The cost of an earthquake simulation shake table ranges from 653–3,000 for compact open-source educational stepper kits and 15,000–45,000 for standard entry-level commercial systems, while bespoke high-capacity servo-hydraulic installations demand individualized engineering estimates from tens of thousands to several hundred thousand dollars depending on specimen weight, axis configuration (uniaxial vs. multi-DOF), and Hydraulic Power Unit (HPU) output. Utilizing an open-architecture COTS servo-hydraulic setup enables research institutions and commercial testing facilities to achieve real-world seismic acceleration and load targets without incurring inflated proprietary OEM pricing.
A 6-DOF shake table can reproduce movement in all three translational directions and around all three rotational axes, making it useful for testing equipment and structures exposed to complex real-world motion. When choosing between a hexapod and an orthogonal actuator system, the key difference is their mechanical arrangement: a hexapod uses coordinated inclined actuators, while an orthogonal system uses actuators arranged along defined movement axes. The better option depends on payload, rotational accuracy, displacement, frequency, and the type of test being performed.
Not every laboratory needs six degrees of freedom. For many applications, a uniaxial or biaxial table is enough. But when pitch, roll, yaw, and combined motion affect the specimen’s response, a properly designed multi-axis system can provide a much more representative test.
Multi-degree-of-freedom shake tables reproduce movement along several axes rather than moving only in one direction. They are used to simulate complex vibration, seismic motion, and other dynamic conditions that a specimen may experience during operation.
A typical 6-DOF system provides three translational movements and three rotational movements. Depending on the design, it may use hydraulic or electromechanical actuators, a moving platform, sensors, and a closed-loop controller.
The six degrees of freedom are:
| Motion | Direction | Description |
| Surge | X-axis | Forward and backward movement |
| Sway | Y-axis | Side-to-side movement |
| Heave | Z-axis | Vertical movement |
| Roll | Rotation around X | Tilting from side to side |
| Pitch | Rotation around Y | Tilting forward and backward |
| Yaw | Rotation around Z | Turning around the vertical axis |
These movements can be applied individually or in combination, depending on the test profile and the system’s capabilities.
For example, a tall equipment cabinet during an earthquake may experience horizontal movement along two directions, vertical acceleration, and rotational effects. A 6-DOF system can reproduce combinations of these movements when the test requirements call for them.
Translational motion moves the specimen from one position to another along an axis. Rotational motion changes its orientation around an axis.
The distinction matters because rotational movement can create different loading conditions across a specimen. For instance, a tall structure experiencing pitch or roll may develop different forces at its upper connections and base.
Rotational testing also requires careful attention to the specimen’s centre of gravity. A small angular movement can create significant displacement at points far from the rotation centre.
A 6-DOF shake table is useful when the test must reproduce combined translational and rotational motion that simpler platforms cannot provide.
Typical reasons include:
The important point is that six axes should serve a defined testing purpose. If your testing needs are simpler or you are still evaluating whether a multi-axis table is necessary, exploring different earthquake simulation shake tables can help clarify when a uniaxial, biaxial, or 6-DOF system makes the most sense. If the test specification only requires horizontal vibration in one direction, a 6-DOF system may add cost and complexity without improving the result.
A hexapod shake table features six actuators connecting a fixed base to a moving platform. The actuators are generally arranged at angles, allowing coordinated length changes to produce translation and rotation.
This arrangement is also known as a Stewart platform. It is widely used in motion simulation because several movement directions can be controlled through one coordinated mechanical structure.
The six actuators connect the base and moving platform through carefully arranged joints. By extending or retracting different actuators in combination, the system changes the platform’s position and orientation.
For example:
A controller calculates the actuator movements required to produce the requested platform position. This process is commonly called inverse kinematics.
The controller also uses sensor feedback to monitor actual platform movement and correct deviations from the target profile.
Hexapod systems can be designed for different payload levels, from relatively compact motion platforms to larger hydraulic configurations.
Their practical payload depends on more than the platform’s rated capacity. It depends on actuator force, actuator angles, joint capacity, platform geometry, centre-of-gravity position, and the required motion.
Another important consideration is that actuator force is shared through the platform’s geometry. The force available in a particular direction may vary depending on the platform position and the combination of movements being commanded.
For heavy specimens, suppliers should provide payload and force performance for the intended operating envelope, not just a maximum static load.
A hexapod can produce controlled rotation around all three axes, which makes it attractive for compact multi-axis testing.
However, the six actuators work together. A command to rotate the platform may require several actuators to move simultaneously. This means the control system must account for geometric relationships and interaction between movement axes.
Axis coupling is not necessarily a design fault. It is part of the hexapod architecture. When multi-axis movements interact, engineers must carefully address cross-coupling and pitch interference through proper kinematic compensation and feedback tuning. The important question is whether the controller can reproduce the required combined motion accurately under the intended load.
The operating range depends on actuator stroke, velocity, force, joint movement, and platform geometry.
At certain platform positions, an actuator may have less remaining travel or a less favourable force direction. This can reduce the available motion in some directions.
Frequency performance also depends on moving mass, structural stiffness, actuator dynamics, hydraulic supply, and control bandwidth.
Ask for performance curves that show the available translation and rotation at the intended payload. A single maximum stroke or frequency figure does not describe the complete operating envelope.
Hexapod shake tables are worth considering for:
They are particularly attractive when the required motion can be achieved within the platform’s force, stroke, and geometry limits.
An orthogonal 6-DOF shake table uses actuators arranged along defined movement directions. Instead of relying on six inclined actuators connected through a hexapod geometry, it uses a more direct arrangement to generate translational and rotational motion.
The exact configuration varies by manufacturer and application. Some designs use separate actuator groups for horizontal, vertical, and rotational movements, while others combine actuator arrangements to achieve the required degrees of freedom.
In an orthogonal system, actuators are arranged to generate movement along specific axes. Horizontal actuators produce X- and Y-direction movement, while vertical actuators can provide Z-direction movement.
Rotational motion is produced through coordinated forces from multiple actuators. For example, applying different vertical movements at separated points on a platform can generate pitch or roll.
The controller coordinates the actuator commands to reproduce the required six-axis motion. The mechanical arrangement can provide a more direct relationship between certain actuator groups and their intended movement directions.
Orthogonal systems can be designed for substantial payloads, particularly where the application requires a large platform and high actuator forces.
Their capacity depends on actuator number, size, arrangement, platform stiffness, support design, and the reaction structure.
For heavy specimen testing, check the force available in each axis and how combined motion affects actuator loading. A system may have strong horizontal capacity but different limits in vertical or rotational movement.
One potential advantage of an orthogonal arrangement is that some actuator groups can be associated more directly with particular movement directions.
This can help with system design and understanding load paths. However, it does not mean every axis is completely independent. A real six-axis platform still involves mechanical interaction, structural flexibility, and control coordination.
Rotational accuracy depends on actuator placement, platform stiffness, sensor arrangement, calibration, and controller performance. The complete system must be assessed under combined loading.
Orthogonal systems can be engineered for large displacement and high-force applications, but performance varies considerably between designs.
The available stroke and velocity depend on actuator specifications and the movement required in each direction. Rotational motion also depends on actuator spacing and platform geometry.
When evaluating a system, request its operating limits for combined translation and rotation. Separate maximum values for each axis may not represent what the system can achieve simultaneously.
An orthogonal actuator arrangement may be suitable for:
The architecture should be selected around the specimen and test profile. An orthogonal design is not automatically better for heavy specimens; its actual force and motion capabilities must be verified.
Both architectures can provide six degrees of freedom, but their mechanical layouts create different design considerations.
| Comparison | Hexapod system | Orthogonal actuator system |
| Actuator arrangement | Six inclined actuators | Actuators arranged along defined axes |
| Motion generation | Coordinated actuator length changes | Coordinated movement from axis-based actuator groups |
| Platform geometry | Commonly compact and enclosed | Can be configured for larger or specialised platforms |
| Rotational movement | Produced through coordinated actuator motion | Produced through coordinated forces at separated points |
| Control | Requires platform kinematics and actuator coordination | Requires multi-axis coordination and compensation |
| Payload | Depends on geometry and actuator capacity | Depends on actuator layout and structural capacity |
| Facility needs | Depends on base size and actuator arrangement | May require more space for separate actuator groups |
| Maintenance | Includes actuators, joints, and connections | Includes actuators, supports, bearings, and connections |
The hexapod uses six inclined actuators connected between two platforms. Its compact geometry allows different actuator movement combinations to create translation and rotation.
An orthogonal system uses actuator arrangements aligned with defined movement directions. Depending on the design, this can make some load paths and actuator functions easier to identify.
Neither architecture is universally superior. The choice depends on platform size, required motion, load distribution, and the available installation space.
For a heavy specimen, compare the force available in each direction rather than looking only at the maximum payload.
A hexapod’s actuator angles influence how force is transferred to the platform. An orthogonal system distributes forces through its separate actuator arrangements, but its capacity still depends on actuator sizing and structural design.
Ask suppliers to demonstrate that the proposed system can achieve the required acceleration and motion with the actual specimen mass, fixtures, and centre of gravity.
Both systems require careful control of rotational motion. A hexapod needs accurate geometric calculations to translate platform movement into six actuator commands.
An orthogonal system also requires coordinated actuator control, sensor feedback, and compensation for mechanical interaction. Its axis-based layout may simplify some aspects of the load path, but it does not eliminate cross-axis effects.
Compare measured rotational accuracy, repeatability, phase response, and performance under combined motion. These are more useful than general claims about control precision.
Frequency capability depends on actuator dynamics, moving mass, platform stiffness, hydraulic supply, and control-system bandwidth.
A compact hexapod may suit applications where its available stroke and force are adequate across the required frequency range. An orthogonal system may suit larger specimens or more demanding motion requirements.
No reliable rule says one architecture always operates at a higher frequency. Request performance data at the intended payload and across the complete test profile.
Hexapods can offer a compact footprint, although their base structure and actuator clearance still need careful planning.
Orthogonal systems may need more room for separate actuator groups, support structures, and maintenance access. Their foundation and reaction requirements depend on the forces and moments generated during operation.
For either arrangement, assess foundation stiffness, anchorage, installation access, hydraulic routing, electrical services, and specimen handling.
A hexapod includes several actuators and mechanical joints. Joint wear, actuator seals, hydraulic connections, and alignment should be considered in the maintenance plan.
An orthogonal system may have more visible or separately accessible actuator assemblies, depending on its layout. It still requires regular checks of bearings, seals, connections, sensors, and hydraulic components.
Before purchasing, ask about spare-part availability, service intervals, actuator replacement procedures, calibration support, and expected maintenance downtime.
Six-axis testing is useful when the specimen’s response depends on combined movement rather than simple translation in one or two directions.
Some equipment can experience horizontal, vertical, and rotational movement during an earthquake. This can affect support connections, mounting arrangements, internal components, and stability.
A 6-DOF system may be appropriate when the qualification test specifically requires combined motion or when rotational effects are important to the equipment’s response.
However, not every seismic qualification requires six degrees of freedom. The applicable test standard and project specification should determine the required input.
Automotive and rail components can experience combined movement caused by vehicle acceleration, vibration, track irregularities, and operating conditions.
Six-axis simulation may be useful for evaluating complex assemblies, mounted equipment, and components whose response depends on movement in several directions.
For smaller components, a simpler vibration system may be sufficient if the test profile does not require rotational input.
Aerospace equipment may be exposed to combined motion during flight, transport, or operation. Avionics assemblies, instruments, and mounted subsystems can require multi-axis testing where orientation and rotational response matter.
A 6-DOF platform can help reproduce defined movement conditions, provided the system meets the required acceleration, frequency, and accuracy limits.
Researchers may use multi-axis systems to study how structural components respond to combined seismic inputs. Rotational effects can influence connections, support conditions, and the behavior of complex specimens.
The need for six-axis testing depends on the research objective. For university and structural laboratories deciding whether fewer axes can meet their experimental goals, comparing biaxial and triaxial shake tables helps weigh payload, motion complexity, and lab requirements before stepping up to full six-axis simulation. A conventional uniaxial or biaxial shake table may still suit many structural experiments.
A uniaxial table is suitable when the test requires movement along one direction. A biaxial table can reproduce movement along two horizontal directions.
Choose a simpler configuration when:
Adding degrees of freedom should improve the test, not simply make the equipment more complex.
A multi-axis system should be selected from a defined test requirement. The term MAST, or multi-axis simulation table, commonly refers to platforms designed to reproduce motion along multiple axes. The selection process should focus on the actual movement and loading the laboratory needs to achieve.
Start by identifying the required motion in all six degrees of freedom. Record the expected acceleration, displacement, velocity, frequency, and rotational input for each axis.
Also identify whether the axes must operate independently or simultaneously. Combined motion can create different actuator and control demands from single-axis testing.
Calculate the complete moving mass, including the specimen, mounting fixture, adapter plates, and other moving components.
Record the centre of gravity and its position relative to the platform. A high or offset centre of gravity can create additional moments and affect actuator loading.
The fixture should be stiff enough to transfer the required forces without introducing unwanted movement or resonance.
Ask suppliers for performance envelopes showing what the system can achieve at the proposed payload.
Check whether maximum acceleration, stroke, and velocity can be achieved together. Also confirm the limits for simultaneous movement across multiple axes.
Specify the required roll, pitch, and yaw angles, along with their velocities and frequencies.
A system may provide adequate rotational movement at low frequencies but perform worse at higher frequencies. Confirm that the proposed platform can reproduce the actual rotational profile under load.
The controller must coordinate the actuators and accurately measure the platform’s response.
Review:
The control system should support the testing workflow, not just operate the actuators.
Compare the complete equipment package, not the platform alone. Include actuators, hydraulic power supply, servo valves, controller, sensors, fixtures, foundation interfaces, installation, commissioning, training, and warranty.
Ask each supplier to confirm performance against the same test profile. This makes it easier to identify differences between quotations.
The cost of a 6-DOF seismic simulation table depends on its payload, actuator arrangement, motion performance, control requirements, and facility infrastructure. A compact hexapod and a large custom orthogonal system can have very different engineering and installation costs.
For a broader breakdown of budget factors across different axis configurations, reviewing a detailed shake table cost and pricing guide can help establish realistic baseline expectations before requesting vendor quotes.
There is no reliable universal price for a six-axis system. Suppliers generally need a detailed technical specification before preparing a meaningful quotation.
Major cost drivers include:
Higher performance requirements can affect several components at once. For example, increasing payload may require larger actuators, stronger platform structures, greater hydraulic flow, and a more substantial foundation.
Hexapod costs are influenced by actuator capacity, joint design, platform geometry, control requirements, and the required motion envelope.
A system requiring high rotational accuracy and substantial payload may need more specialised actuators, joints, sensors, and mechanical components.
The compact arrangement can be attractive, but it does not automatically make a hexapod cheaper than an orthogonal system.
Orthogonal systems can require separate actuator groups, larger support structures, and additional space for installation and maintenance.
Costs depend on the number and size of actuators, reaction structure, platform dimensions, control architecture, and required performance in each axis.
Custom configurations for heavy specimens can involve significant mechanical and civil engineering work.
A procurement budget should also include:
These items can make a noticeable difference to the final project budget. Request a complete scope of supply before comparing prices.
Begin with the test profiles the laboratory genuinely needs. Avoid specifying maximum payload, stroke, frequency, and rotational movement unless the testing programme requires them.
If the laboratory mainly tests heavy structural specimens with horizontal motion, a simpler system may provide better value than a six-axis platform. When standard platforms cannot handle unusual payloads, high overturning moments, or specialized multi-axis test envelopes, a custom MAST shake table can be engineered around your exact requirements without paying for unnecessary complexity elsewhere.
A 6-DOF shake table is a testing platform that provides three translational movements—X, Y, and Z—and three rotational movements—roll, pitch, and yaw. It is used to reproduce complex motion for seismic, structural, automotive, aerospace, and equipment testing.
A hexapod uses six inclined actuators connecting a fixed base to a moving platform. An orthogonal system uses actuators arranged along defined movement directions, with coordinated forces producing translation and rotation. Their performance depends on the specific mechanical and control design.
Either architecture can be designed for heavy specimens. The better choice depends on actuator force, payload, centre of gravity, platform geometry, stroke, and foundation capacity. Compare performance under the actual specimen load rather than relying on the architecture name.
Neither architecture is automatically more accurate. Rotational accuracy depends on actuator arrangement, platform stiffness, sensor calibration, control algorithms, and performance under combined loading. Request measured accuracy and repeatability data for the intended operating conditions.
It is required when the test profile includes rotational movement or when pitch, roll, and yaw significantly affect the specimen’s response. Determine the need based on the test objective, applicable standard, and expected real-world loading.
MAST stands for multi-axis simulation table. It is designed to reproduce movement across multiple directions, often including all six degrees of freedom. MAST systems are used when a test requires combined translational and rotational input.
There is no single standard price. Cost depends on payload, actuator force, motion range, frequency, control precision, system architecture, foundation work, and installation. A supplier needs the complete technical specification to provide a realistic quotation.
Choosing between a hexapod and an orthogonal 6-DOF shake table depends on the required motion, specimen loading, and facility conditions. Hexapods offer coordinated movement through six inclined actuators, while orthogonal systems use actuator arrangements aligned with defined movement directions.
Before selecting either architecture, define the complete test profile, calculate moving mass and centre of gravity, and check translation and rotation limits under load. A well-matched system will provide the motion your laboratory actually needs without adding unnecessary cost or complexity. To explore tailored multi-axis configurations and engineered custom shake tables or complete testing systems, reach out to our engineering team for a project-specific evaluation.
Whether you are evaluating a compact hexapod Stewart platform or a high-payload orthogonal actuator arrangement, our engineering team can help you define your motion envelope, COTS control architecture, and facility requirements.